Triad Magnetics Industrial Control Transformers

Results: 69
Select Image Part # Mfr. Description Datasheet Availability Pricing (USD) Filter the results in the table by unit price based on your quantity. Qty. RoHS ECAD Model Power Rating Primary Voltage Rating Secondary Voltage Rating Secondary Current Rating Mounting Style Primary Winding Secondary Winding Length Width Height
Triad Magnetics Industrial Control Transformers CLASS 2 XFMR - :120/240VAC at 50/60Hz, OUT: 12VAC at 50VA, QC's ON TOP 170Factory Stock Available
Min.: 1
Mult.: 1

50 VA 120 V, 240 V 12 V 4.17 A Bracket, Panel Mount Single Primary Winding Single Secondary Winding 57 mm 95 mm 71.5 mm

Triad Magnetics Industrial Control Transformers UL/cUL - 208/240V Class II Control Xfmr 24V at 2.08A w/Quick Connects 18Factory Stock Available
Min.: 1
Mult.: 1

50 VA 208 V, 240 V 24 V 2.08 A Bracket, Panel Mount Single Primary Winding Single Secondary Winding 71.5 mm 92.5 mm 56.5 mm
Triad Magnetics Industrial Control Transformers UL/cUL - 240V Class II Control Xfmr 24V at 1.67A w/Quick Connect Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

40 VA 240 V 24 V 1.67 A Bracket Mount Single Primary Winding Single Secondary Winding 61 mm 92.5 mm 56.5 mm
Triad Magnetics Industrial Control Transformers UL/cUL - 208/240V Class II Control Xfmr 24V at 1.67A w/Quick Connects Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

40 VA 208 V, 240 V 24 V 1.67 A Bracket Mount Single Primary Winding Single Secondary Winding 61 mm 92.5 mm 56.5 mm
Triad Magnetics Industrial Control Transformers CLASS 2 XFMR - :240VAC at 50/60Hz, OUT: 24VAC at 40VA, QC's ON TOP Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

40 VA 240 V 24 V 1.67 A Bracket Mount Single Primary Winding Single Secondary Winding 2.6 in 2.22 in 2.34 in
Triad Magnetics Industrial Control Transformers CLASS 2 XFMR - :240VAC at 50/60Hz, OUT: 12VAC at 40VA, QC's ON TOP Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

40 VA 240 V 12 V 3.34 A Bracket Mount Single Primary Winding Single Secondary Winding 2.6 in 2.22 in 2.34 in
Triad Magnetics Industrial Control Transformers CLASS 2 XFMR:120/208/240, 50/60 Hz OUT: 24V at 40VA, QUICK CONNECT S ON TOP Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

40 VA 120 V, 208 V, 240 V 24 V 1.67 A Bracket Mount Single Primary Winding Single Secondary Winding 2.6 in 2.22 in 2.34 in
Triad Magnetics Industrial Control Transformers CLASS 2 XFMR : 208/240 VAC, 50/60 HZ OUT: 24 VA at 40VA, QUICK CONNECTS ON TOP: Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

40 VA 208 V, 240 V 24 V 1.67 A Bracket Mount Single Primary Winding Single Secondary Winding 2.6 in 2.22 in 2.34 in
Triad Magnetics Industrial Control Transformers CLASS 2 XFMR - :208/240VAC at 50/60Hz, OUT: 12VAC at 40VA, QC's ON TOP Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

40 VA 208 V, 240 V 12 V 3.34 A Bracket Mount Single Primary Winding Single Secondary Winding 2.6 in 2.22 in 2.34 in
Triad Magnetics Industrial Control Transformers CLASS 2 XFMR - :120VAC at 50/60Hz, OUT: 24VAC at 50VA, QC's ON TOP Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

50 VA 120 V 24 V 2.08 A Bracket, Panel Mount Single Primary Winding Single Secondary Winding 57 mm 95 mm 71.5 mm
Triad Magnetics Industrial Control Transformers UL/cUL - 240V Class II Control Xfmr 24V at 2.08A w/Quick Connect on top Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

50 VA 240 V 24 V 2.08 A Bracket Mount Single Primary Winding Single Secondary Winding 2.74 in 3.64 in 2.22 in
Triad Magnetics Industrial Control Transformers CLASS 2 XFMR - :120VAC at 50/60Hz, OUT: 12VAC at 50VA, QC's ON TOP Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

50 VA 120 V 12 V 4.17 A Bracket, Panel Mount Single Primary Winding Single Secondary Winding 57 mm 95 mm 71.5 mm
Triad Magnetics Industrial Control Transformers CLASS 2 XFMR - :240VAC at 50/60Hz, OUT: 12VAC at 50VA, QC's ON TOP Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

50 VA 240 V 12 V 4.17 A Bracket Mount Single Primary Winding Single Secondary Winding 2.74 in 3.64 in 2.22 in
Triad Magnetics Industrial Control Transformers CLASS 2 XFMR - : 120/208/240, 50/60 Hz OUT: 24V at 50VA, QUICK CONNECT S ON TOP Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

50 VA 120 V, 208 V, 240 V 24 V 2.08 A Bracket Mount Single Primary Winding Single Secondary Winding 2.74 in 3.64 in 2.22 in
Triad Magnetics Industrial Control Transformers UL/cUL - 120/208/240V Class II Control Xfmr 24V at 2.08A w/Leads Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

50 VA 120 V, 208 V, 240 V 24 V 2.08 A Bracket Mount Single Primary Winding Single Secondary Winding 71.5 mm 92.5 mm 56.5 mm
Triad Magnetics Industrial Control Transformers CLASS2 XFMR - : 120/208/240, 50/60 Hz OUT: 12V at 50VA, QUICK CONNECT S ON TOP Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

50 VA 120 V, 208 V, 240 V 12 V 4.17 A Bracket Mount Single Primary Winding Single Secondary Winding 2.74 in 3.64 in 2.22 in
Triad Magnetics Industrial Control Transformers UL/cUL - 208/240V Class II Control Xfmr 24V at 2.08A w/Leads Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

50 VA 208 V, 240 V 24 V 2.08 A Bracket, Panel Mount Single Primary Winding Single Secondary Winding 2.74 in 3.64 in 2.22 in
Triad Magnetics Industrial Control Transformers CLASS 2 XFMR - :208/240VAC at 50/60Hz, OUT: 12VAC at 50VA, QC's ON TOP Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

50 VA 208 V, 240 V 12 V 4.17 A Bracket, Panel Mount Single Primary Winding Single Secondary Winding 2.74 in 3.64 in 2.22 in
Triad Magnetics Industrial Control Transformers UL/cUL - 208V, 240V Class II Control Xfrmr, 12V at 4.16A w/ Leads Non-Stocked Lead-Time 16 Weeks
Min.: 1
Mult.: 1

50 VA 208 V, 240 V 12 V 4.17 A Bracket, Panel Mount Single Primary Winding Single Secondary Winding 2.74 in 3.64 in 2.22 in