Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
- 2-5700-IG1-P10-DD-2A
- E-T-A
-
1:
$35.04
-
20In Stock
|
Mouser Part No
457-25700IG1P10DD2A
|
E-T-A
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
|
|
20In Stock
|
|
Min.: 1
Mult.: 1
|
|
|
2-5700
|
Thermal Circuit Breakers
|
Overcurrent Protection
|
2 A
|
250 VAC
|
28 VDC
|
1 Pole
|
Push to Reset
|
- 20 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
- 2-5700-IG1-P10-DD-30A
- E-T-A
-
1:
$53.68
-
15In Stock
|
Mouser Part No
457-25700IG1P10DD30A
|
E-T-A
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
|
|
15In Stock
|
|
Min.: 1
Mult.: 1
|
|
|
2-5700
|
Thermal Circuit Breakers
|
Overcurrent Protection
|
30 A
|
250 VAC
|
28 VDC
|
1 Pole
|
Push to Reset
|
- 20 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
- 2-5700-IG1-P10-DD-4A
- E-T-A
-
1:
$35.04
-
7In Stock
|
Mouser Part No
457-25700IG1P10DD4A
|
E-T-A
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
|
|
7In Stock
|
|
Min.: 1
Mult.: 1
|
|
|
2-5700
|
Thermal Circuit Breakers
|
Overcurrent Protection
|
4 A
|
250 VAC
|
28 VDC
|
1 Pole
|
Push to Reset
|
- 20 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
- 2-5700-IG1-P10-DD-5A
- E-T-A
-
1:
$36.63
-
19In Stock
-
150Expected 2026/11/27
|
Mouser Part No
457-25700IG1P10DD5A
|
E-T-A
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
|
|
19In Stock
150Expected 2026/11/27
|
|
Min.: 1
Mult.: 1
|
|
|
2-5700
|
Thermal Circuit Breakers
|
Overcurrent Protection
|
5 A
|
250 VAC
|
28 VDC
|
1 Pole
|
Push to Reset
|
- 20 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
- 2-5700-IG1-P10-DD-6A
- E-T-A
-
1:
$23.76
-
7In Stock
-
10Expected 2026/12/25
|
Mouser Part No
457-25700IG1P10DD6A
|
E-T-A
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
|
|
7In Stock
10Expected 2026/12/25
|
|
Min.: 1
Mult.: 1
|
|
|
2-5700
|
Thermal Circuit Breakers
|
Overcurrent Protection
|
6 A
|
250 VAC
|
28 VDC
|
1 Pole
|
Push to Reset
|
- 20 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
- 2-5700-IG1-P10-DD-8A
- E-T-A
-
1:
$36.34
-
1In Stock
-
40On Order
|
Mouser Part No
457-25700IG1P10DD8A
|
E-T-A
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
|
|
1In Stock
40On Order
Stock:
1 Can Dispatch Immediately
On Order:
10 Expected 2026/11/16
30 Expected 2026/12/07
Factory Lead Time:
6 Weeks
|
|
Min.: 1
Mult.: 1
|
|
|
2-5700
|
Thermal Circuit Breakers
|
Overcurrent Protection
|
8 A
|
250 VAC
|
28 VDC
|
1 Pole
|
Push to Reset
|
- 20 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Circuit Breakers Single pole thermal circuit Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-t
- 2-5700-IG2-K10-DD-15A
- E-T-A
-
1:
$43.46
-
5In Stock
|
Mouser Part No
457-25700IG2K10DD15A
|
E-T-A
|
Circuit Breakers Single pole thermal circuit Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-t
|
|
5In Stock
|
|
Min.: 1
Mult.: 1
|
|
|
2-5700
|
Thermal Circuit Breakers
|
Overcurrent Protection
|
15 A
|
250 VAC
|
28 VDC
|
1 Pole
|
Push to Reset
|
- 20 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration;S-type
- 2-5700-IG2-K10-DD-25A
- E-T-A
-
1:
$43.14
-
11In Stock
|
Mouser Part No
457-25700IG2K10DD25A
|
E-T-A
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration;S-type
|
|
11In Stock
|
|
Min.: 1
Mult.: 1
|
|
|
2-5700
|
Thermal Circuit Breakers
|
Overcurrent Protection
|
25 A
|
250 VAC
|
28 VDC
|
1 Pole
|
Push to Reset
|
- 20 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
- 2-5700-IG2-P10-10A
- E-T-A
-
1:
$32.26
-
2In Stock
|
Mouser Part No
457-25700IG2P1010A
|
E-T-A
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
|
|
2In Stock
|
|
Min.: 1
Mult.: 1
|
|
|
2-5700
|
Thermal Circuit Breakers
|
Overcurrent Protection
|
10 A
|
250 VAC
|
28 VDC
|
1 Pole
|
Push to Reset
|
- 20 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
- 2-5700-IG2-P10-20A
- E-T-A
-
1:
$32.26
-
8In Stock
|
Mouser Part No
457-25700IG2P1020A
|
E-T-A
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
|
|
8In Stock
|
|
Min.: 1
Mult.: 1
|
|
|
2-5700
|
Thermal Circuit Breakers
|
Overcurrent Protection
|
20 A
|
250 VAC
|
28 VDC
|
1 Pole
|
Push to Reset
|
- 20 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
- 2-5700-IG2-P10-25A
- E-T-A
-
1:
$32.26
-
5In Stock
|
Mouser Part No
457-25700IG2P1025A
|
E-T-A
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
|
|
5In Stock
|
|
Min.: 1
Mult.: 1
|
|
|
2-5700
|
Thermal Circuit Breakers
|
Overcurrent Protection
|
25 A
|
250 VAC
|
28 VDC
|
1 Pole
|
Push to Reset
|
- 20 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
- 2-5700-IG2-P10-2A
- E-T-A
-
1:
$32.26
-
10In Stock
|
Mouser Part No
457-25700IG2P102A
|
E-T-A
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
|
|
10In Stock
|
|
Min.: 1
Mult.: 1
|
|
|
2-5700
|
Thermal Circuit Breakers
|
Overcurrent Protection
|
2 A
|
250 VAC
|
28 VDC
|
1 Pole
|
Push to Reset
|
- 20 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
- 2-5700-IG2-P10-DD-10A
- E-T-A
-
1:
$36.11
-
50In Stock
-
50Expected 2026/12/14
|
Mouser Part No
457-25700IG2P10DD10A
|
E-T-A
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
|
|
50In Stock
50Expected 2026/12/14
|
|
Min.: 1
Mult.: 1
|
|
|
2-5700
|
Thermal Circuit Breakers
|
Overcurrent Protection
|
10 A
|
250 VAC
|
28 VDC
|
1 Pole
|
Push to Reset
|
- 20 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Circuit Breakers Single pole high performance thermal circuit breaker with tease-free, trip-free, snap action mechanism and push/pull on/off manual actuation (M-type TO CBE to EN 60934). An indicator band on the push button clearly shows the tripped/off position. Thr
- 412-K54-FN2-10A
- E-T-A
-
1:
$106.45
-
6In Stock
|
Mouser Part No
457-412-K54-FN2-10A
|
E-T-A
|
Circuit Breakers Single pole high performance thermal circuit breaker with tease-free, trip-free, snap action mechanism and push/pull on/off manual actuation (M-type TO CBE to EN 60934). An indicator band on the push button clearly shows the tripped/off position. Thr
|
|
6In Stock
|
|
Min.: 1
Mult.: 1
|
|
|
412
|
Circuit Breakers
|
Thermal
|
10 A
|
115 VAC
|
28 VDC
|
1 Pole
|
Push-Pull
|
- 55 C
|
+ 75 C
|
Non-Illuminated
|
|
|
|
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
- 2-5700-IG1-P10-A3-0.3A
- E-T-A
-
1:
$40.74
-
3In Stock
|
Mouser Part No
457-5700IG1P10A30.3A
|
E-T-A
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
|
|
3In Stock
|
|
Min.: 1
Mult.: 1
|
|
|
Feb-00
|
Thermal Circuit Breakers
|
Overcurrent Protection
|
300 mA
|
250 VAC
|
28 VDC
|
1 Pole
|
Push to Reset
|
- 20 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
- 2-5700-IG1-P10-A3-0.5A
- E-T-A
-
1:
$40.74
-
10In Stock
|
Mouser Part No
457-5700IG1P10A30.5A
|
E-T-A
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
|
|
10In Stock
|
|
Min.: 1
Mult.: 1
|
|
|
Feb-00
|
Thermal Circuit Breakers
|
Overcurrent Protection
|
500 mA
|
250 VAC
|
28 VDC
|
1 Pole
|
Push to Reset
|
- 20 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
- 2-5700-IG1-P10-DD-0.8A
- E-T-A
-
1:
$41.04
-
18In Stock
|
Mouser Part No
457-5700IG1P10DD0.8A
|
E-T-A
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
|
|
18In Stock
|
|
Min.: 1
Mult.: 1
|
|
|
2-5700
|
Thermal Circuit Breakers
|
Overcurrent Protection
|
800 mA
|
250 VAC
|
28 VDC
|
1 Pole
|
Push to Reset
|
- 20 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
- 2-5700-IG1-P10-DD-2.5A
- E-T-A
-
1:
$38.09
-
4In Stock
|
Mouser Part No
457-5700IG1P10DD2.5A
|
E-T-A
|
Circuit Breakers Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration; S-typ
|
|
4In Stock
|
|
Min.: 1
Mult.: 1
|
|
|
2-5700
|
Thermal Circuit Breakers
|
Overcurrent Protection
|
2.5 A
|
250 VAC
|
28 VDC
|
1 Pole
|
Push to Reset
|
- 20 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Circuit Breakers Min Ord Qty 10. The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
- 3120-N32V-N7T1-SGRXG4-6A
- E-T-A
-
1:
$38.63
-
7In Stock
|
Mouser Part No
457-N32VN7T1SGRXG46A
|
E-T-A
|
Circuit Breakers Min Ord Qty 10. The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
|
|
7In Stock
|
|
Min.: 1
Mult.: 1
|
|
|
3120-N-T1
|
Thermal Circuit Breakers
|
Overcurrent Protection
|
6 A
|
240 VAC
|
50 VDC
|
2 Pole
|
Pushbutton Dual
|
- 30 C
|
+ 60 C
|
Non-Illuminated
|
|
|
|
|
Circuit Breakers Single pole high performance thermal circuit breaker with tease-free, trip-free, snap action mechanism and push/pull on/off manual actuation (M-type TO CBE to EN 60934). An indicator band on the push button clearly shows the tripped/off position. Thr
- 412-K14-LN2-2A
- E-T-A
-
1:
$100.98
-
4In Stock
-
72On Order
|
Mouser Part No
457-412-K14-LN2-2A
|
E-T-A
|
Circuit Breakers Single pole high performance thermal circuit breaker with tease-free, trip-free, snap action mechanism and push/pull on/off manual actuation (M-type TO CBE to EN 60934). An indicator band on the push button clearly shows the tripped/off position. Thr
|
|
4In Stock
72On Order
Stock:
4 Can Dispatch Immediately
On Order:
52 Expected 2026/11/10
20 Expected 2027/03/30
Factory Lead Time:
23 Weeks
|
|
Min.: 1
Mult.: 1
|
|
|
412
|
Circuit Breakers
|
Thermal
|
2 A
|
115 VAC
|
28 VDC
|
1 Pole
|
Push-Pull
|
- 55 C
|
+ 75 C
|
Non-Illuminated
|
|
|
|
|
Circuit Breakers Single pole high performance thermal circuit breaker with tease-free, trip-free, snap action mechanism and push/pull on/off manual actuation (M-type TO CBE to EN 60934). An indicator band on the push button clearly shows the tripped/off position. Thr
- 412-K14-LN2-30A
- E-T-A
-
1:
$87.26
-
5In Stock
-
39On Order
|
Mouser Part No
457-412-K14-LN2-30A
|
E-T-A
|
Circuit Breakers Single pole high performance thermal circuit breaker with tease-free, trip-free, snap action mechanism and push/pull on/off manual actuation (M-type TO CBE to EN 60934). An indicator band on the push button clearly shows the tripped/off position. Thr
|
|
5In Stock
39On Order
Stock:
5 Can Dispatch Immediately
On Order:
10 Pending
17 Expected 2027/02/05
12 Expected 2027/02/22
Factory Lead Time:
25 Weeks
|
|
Min.: 1
Mult.: 1
|
|
|
412
|
Circuit Breakers
|
Thermal
|
30 A
|
115 VAC
|
28 VDC
|
1 Pole
|
Push-Pull
|
- 55 C
|
+ 75 C
|
Non-Illuminated
|
|
|
|
|
Circuit Breakers Single pole high performance thermal circuit breaker with tease-free, trip-free, snap action mechanism and push/pull on/off manual actuation (M-type TO CBE to EN 60934). An indicator band on the push button clearly shows the tripped/off position. Thr
- 412-K14-LN2-7.5A
- E-T-A
-
1:
$92.21
-
10In Stock
-
90On Order
|
Mouser Part No
457-412-K14-LN2-7.5A
|
E-T-A
|
Circuit Breakers Single pole high performance thermal circuit breaker with tease-free, trip-free, snap action mechanism and push/pull on/off manual actuation (M-type TO CBE to EN 60934). An indicator band on the push button clearly shows the tripped/off position. Thr
|
|
10In Stock
90On Order
Stock:
10 Can Dispatch Immediately
On Order:
39 Expected 2026/11/10
51 Expected 2027/02/05
Factory Lead Time:
28 Weeks
|
|
Min.: 1
Mult.: 1
|
|
|
412
|
Circuit Breakers
|
Thermal
|
7.5 A
|
115 VAC
|
28 VDC
|
1 Pole
|
Push-Pull
|
- 55 C
|
+ 75 C
|
Non-Illuminated
|
|
|
|
|
Circuit Breakers Single pole high performance thermal circuit breaker with tease-free, trip-free, snap action mechanism and push/pull on/off manual actuation (M-type TO CBE to EN 60934). An indicator band on the push button clearly shows the tripped/off position. Thr
- 412-K54-LN2-15A
- E-T-A
-
1:
$131.17
-
2In Stock
-
3Expected 2026/11/30
|
Mouser Part No
457-412-K54-LN2-15A
|
E-T-A
|
Circuit Breakers Single pole high performance thermal circuit breaker with tease-free, trip-free, snap action mechanism and push/pull on/off manual actuation (M-type TO CBE to EN 60934). An indicator band on the push button clearly shows the tripped/off position. Thr
|
|
2In Stock
3Expected 2026/11/30
|
|
Min.: 1
Mult.: 1
|
|
|
412
|
Circuit Breakers
|
Thermal
|
15 A
|
115 VAC
|
28 VDC
|
1 Pole
|
Push-Pull
|
- 55 C
|
+ 75 C
|
Non-Illuminated
|
|
|
|
|
Circuit Breakers The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
- 3120-N321-P7T1-W19DG4-10A
- E-T-A
-
1:
$48.85
-
14In Stock
|
Mouser Part No
457-N321P7T1W19DG410
|
E-T-A
|
Circuit Breakers The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
|
|
14In Stock
|
|
Min.: 1
Mult.: 1
|
|
|
3120-N
|
Thermal Circuit Breakers
|
Overcurrent Protection
|
10 A
|
240 VAC
|
50 VDC
|
2 Pole
|
Rocker
|
- 30 C
|
+ 60 C
|
Illuminated
|
|
|
|
|
Circuit Breakers TA35 Circuit Breaker, 2 Pole, 10 Amp, F2, Thermal-Magnetic, Snap-in Mounting
- 3-150-706
- Schurter
-
1:
$52.00
-
14In Stock
|
Mouser Part No
693-3-150-706
|
Schurter
|
Circuit Breakers TA35 Circuit Breaker, 2 Pole, 10 Amp, F2, Thermal-Magnetic, Snap-in Mounting
|
|
14In Stock
|
|
Min.: 1
Mult.: 1
|
|
|
TA35
|
Circuit Breakers
|
Thermal Magnetic
|
10 A
|
240 V
|
32 V
|
2 Pole
|
Rocker
|
- 30 C
|
+ 60 C
|
Non-Illuminated
|
|
|